Lucent DDM-2000 OC-3 User And Service Manual page 946

Tarp release 13 and later volume ii
Table of Contents

Advertisement

DLP-528
: Detailed Level Procedure
Page 10 of 12
33. Was response correct?
If YES, then proceed to Step 36.
If NO, then continue with Step 34.
34. Wait approximately 10 minutes for the network to stabilize, exit term, then
repeat this procedure from Step 23. If the second attempt to download
software fails, do Trouble Clearing: TAP-122. You may have to go to the
remote site.
35. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
36. Wait approximately 5 minutes then verify communications can be
reestablished with far-end shelf using rtrv-map-network command. Verify
that Comm. Status is good (not FAILED) as indicated by a blank in the
report.
37. Is communication status good between local and remote shelf?
If YES, then proceed to Step 40.
If NO, then continue with Step 38.
38. Dispatch technician to remote site and perform local software download
procedures.
Reference: DLP-525
39. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
40. Are you going to use the apply command at this time to load dormant version
of software?
If YES, then continue with Step 41.
If NO, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
41. Use rlgn:tid command to remotely login to far-end shelf.
Reference: DLP-522
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285

Advertisement

Table of Contents
loading

Table of Contents