363-206-285
Issue 2, February 2000
Response:
Ensure PC is connected to the front CIT (CIT-1). If floppies are being used,
ensure the first (number 1) diskette is installed in floppy drive. If hard drive is
being used, ensure you are in the correct directory.
24. Enter term or term COMn command, where n = 1 or 2. If term is entered
without the COMn option, then COM1 will be selected by default. If after starting
the terminal emulator you see the message Can't find script <init>,
disregard it.
Response:
25.
NOTE:
The default shelf is the shelf physically connected to the PC. To set baud
rate automatically, enter two carriage returns (<cr>), two lower case "a"s
(aa), or two upper case "A"s (AA). All other characters are ignored.
Enter two carriage returns.
Response:
26. Was response correct?
If YES, then proceed to Step 28.
If NO, then continue with Step 27.
27. Check PC to CIT port connections. Make sure the cable is connected between
the PC COM( ) port and the CIT connector on the DDM-2000. If the rear CIT
connector is being used on the DDM-2000, make sure a null modem is
installed on the port. Check term setup and make sure the com port selected
matches the port (COM( )) on the PC that is connected to the CIT port on the
SROF
/* Status, Requested Operation Failed */
/* Software download failed; check Target
NE (TID value). */
Two brief messages are printed and you are instructed to
Press any key to continue . . . after the
second message. After you press any key, the terminal
emulator is loaded and the terminal responds as follows:
Interface ready. (Type Alt-h for help.)
Communications established.
PC prompts with:
/* Enter a shelf number from 1 to 8 */
shelf [default] =
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-528
Page 7 of 12