DLP-507
: Detailed Level Procedure
Page 4 of 4
9.
NOTE:
Since cross-connections associated with BBG19 DS3 circuit packs are
non-path-switched locked cross-connections, a BBG19 DS3 circuit pack
installed in FUNCTION UNITS group slot ( ) 1 at one terminating node is
associated with the BBG19 DS3 circuit pack in FUNCTION UNITS group
slot ( ) 2(P) at the other terminating node.
NOTE:
If response is not correct in the following procedures, replace the BBG19
DS3 circuit pack.
Seat BBG19 DS3 circuit packs in FUNCTION UNITS group slots A ( ), B ( ) or
C ( ) being equipped.
Response:
10. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
FAULT LED on the BBG19 DS3 lights for about 20
seconds then goes off. ACTIVE LED lights on BBG19
DS3 circuit pack.