Lucent DDM-2000 OC-3 User And Service Manual page 953

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
Retrieve Generic Software Version ID
1.
Is a CIT available?
If YES, then continue with Step 2.
If NO, then proceed to Step 5.
2.
Connect CIT to User Panel and establish session.
Reference: DLP-521
3.
Use the rtrv-eqpt:sysctl command to retrieve generic software version
number.
Response:
4.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
5.
NOTE:
When the ACO button is depressed, all LEDs and the 7-segment display
on the SYSCTL light. If the ACO button is released within 2 seconds, the
LED test completes and the 7-segment display and all LEDs will revert to
normal operation. If the ACO button is depressed longer than 2 seconds,
the 7-segment display goes blank for 2 seconds and then each digit of
the generic software version code is scrolled through the display. The
LEDs remain lighted while the code is being displayed. When the ACO
button is released, the LEDs remain lighted until the full software version
code is displayed. If the ACO button is still depressed when the software
version code has completed cycling, the display goes blank for 2 seconds
and starts cycling through the software version code again. This
continues as long as the ACO button is depressed. When the ACO
button is released the cycle will complete and the display and all LEDs go
to normal operation.
Depress and hold (for longer than 2 seconds) the ACO button on the User
Panel.
Response:
6.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
System outputs an Equipage and Version Report
which contains the program version presently loaded into
the system.
All LEDs and the 7-segment display light. The display
goes blank for 2 seconds and then scrolls through the full
software version code.
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-531
Page 1 of 2