Lucent DDM-2000 OC-3 User And Service Manual page 868

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
2.
NOTE:
Three IMA LAN circuit packs can be installed in LOW SPEED GROUP A,
B, or C, when the associated FUNCTION UNITS group A, B, or C is
equipped with the BBG2B MXRVOs. Only one IMA LAN circuit pack is
allowed in a LOW SPEED GROUP, if the associated FUNCTION UNITS
group is equipped with the BBG2 MXRVOs.
Seat IMA LAN circuit pack in required slot of LOW SPEED group being
equipped.
Response:
3.
Repeat this procedure from Step 1 for each service IMA LAN circuit pack
being installed.
4.
Install 177A Retainer Cards into all unequipped service LOW SPEED slots.
5.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
FAULT LED on IMA LAN circuit pack lights and may
remain lighted for about 40 seconds and then goes off.
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-518
Page 2 of 2

Advertisement