Lucent DDM-2000 OC-3 User And Service Manual page 723

Tarp release 13 and later volume ii
Table of Contents

Advertisement

TAP-117
: Trouble Clearing
Page 1 of 4
1.
Connect the CIT to the CIT connector on the near-end User Panel and log in to
the near-end system.
Reference: DLP-521
2.
NOTE:
The rtrv-alm: command can be used to display a report of active
alarm and status conditions. The Commands and Reports section of this
manual gives a description of the command.
NOTE:
The Active Alarm and Status Report is output automatically
following CIT log in. The report shown in Figure 1 is an example that
shows one entry. There may be many entries in the actual report.
Note the information in the Source Address and Description columns for
the top entry/entries above the first single-dashed line in the Active Alarm
and Status Report (Figure 1) (for example,
ne-acty
m2-1-1-1 MM-DD HH:MM:SS nsa inc. VT AIS).
/* Active Alarms and Status Report
=============================================================
Alarm
Source
Level
Address
=============================================================
ne-acty
m2-1-1-1
-------------------------------------------------------------
*/
Figure 1 – Example of Active Alarms and Status Report
Clear NE ACTY Alarm Only
Date
Time
Detected
MM-DD HH:MM:SS
DDM-2000 OC-3 M
Issue 2, February 2000
Srv
Description
nsa
inc. VT AIS
ULTIPLEXER
363-206-285