DLP-526
: Detailed Level Procedure
Page 5 of 8
Remote CIT Location
7.
At the remote CIT location, set the terminal parameters to match those set at
the DDM-2000 location. Refer to manufacturer's manual for instructions on
setting modem parameters.
8.
Connect the remote modem to the CIT terminal using the appropriate modem
cable. Tables B and C list the pins for the DB-25 connector and DB-9
connector, respectively.
9.
Verify the telephone line is plugged into the modem.
10.
NOTE:
Characters other than a question mark (?), carriage return (<cr>),
semicolon (;), dollar sign ($), or the numbers 1 through 8 are ignored.
Typing a carriage return more than twice by mistake will cause the
system to start a session with the default shelf. The default shelf is the
shelf that is physically connected to the CIT.
NOTE:
Security is available to protect against unauthorized access to the
system. If security is enabled, users must enter a valid login and
password to access the system.
NOTE:
To set baud rate automatically, enter two carriage returns (<cr>), two
lowercase "a"s (aa), or two uppercase "A"s (AA). All other characters are
ignored.
Dial into the DDM-2000 system by entering the correct telephone number.
When the modem at the DDM-2000 end answers, establish a login session by
pressing RETURN (<cr>) until the system answers. CIT should return with the
following prompt:
/* Enter a shelf number from 1 to 8 */
shelf [default] =
11.
NOTE:
Entering just a carriage RETURN at the shelf prompt will connect you to
the shelf physically connected to the CIT.
Enter the shelf number and/or carriage RETURN for the shelf being accessed.
Response:
CIT prompts with login <
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285