Lucent DDM-2000 OC-3 User And Service Manual page 447

Tarp release 13 and later volume ii
Table of Contents

Advertisement

NTP-047
: System Turnup
Page 11 of 12
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
TRMTR/
RCVR
1A
1B
OC-48
TRMTR/
RCVR
1A
1B
(0X1)
(NS)
DDM-2000 OC-12 DCC Network Side (NS)/User Side (US) Defaults (set-fecom:nsus=ns/us)
24/29-Type
OLIUs
(0X1 Rings
application)
Figure 3 – Example of OC-12 Single Homed User Side/Network Side Value
FT-2000 OC-48
OC-48
TRMTR/
RCVR
2B
3
7B 8A
2A
3A
8B
LS INTFC
FT-2000 OC-48
TRMTR/
RCVR
7B 8A
2A
2B
3A
3
LS INTFC
(US)
OC-12 Path Switched Ring with
OC-3 Shelves with OC-12 Optics
Faceplate Connector
Node 2
DDM-2000
Passes Through
Undropped STSs
OC-12
OC-12
MAIN 2
MAIN 1
US
NS
A
B
C
A
B
C
1
2(P)
1
2(P)
1
2(P)
MAIN 1
MAIN 2
dcc-m1
dcc-m2
US
NS
Settings
DDM-2000 OC-3 M
Issue 2, February 2000
FT-2000 OC-48
TRMTR/
TRMTR/
RCVR
RCVR
1A
1B
2A
2B
3A
3
7B 8A
LS INTFC
OC-48
8B
OC-12
OC-12
FN-A
FN-B
dcc-a
dcc-b
NS
NS
ULTIPLEXER
363-206-285
8B
Node 1
DDM-2000
OC-12
MAIN 1
MAIN 2
US
NS
A
B
C
A
B
C
1
2(P)
1
2(P)
1
2(P)
FN-C
dcc-c
NS