Lucent DDM-2000 OC-3 User And Service Manual page 745

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
Clear Trouble During IMA LAN Program Upgrade
1.
NOTE:
Program installation may fail due to failure of communication link between
PC and DDM-2000, failure of the floppy disk or hard disk on the PC,
failure or loss of power in the PC, or failure of the SYSCTL or OHCTL.
See ins-prog: and cpy-prog: command pages in the Commands
and Reports section of Volume 1 of this manual for other failure
indications.
Was the following message received?
SSTP
/* Status,execution stopped. */
/* Target NE does not support this feature.*/
If YES, then continue with Step 2.
If NO, then proceed to Step 4.
2.
Indications are that you are trying to download IMA LAN software into a
network element that does not support this feature (i.e. installing IMA LAN
software into an OC-3 shelf running Release 13.0).
If you need assistance, notify your supervisor, your local technical support
organization, or call Lucent Technologies RTAC, per local operating
instructions.
3.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
4.
Was the following message received?
/* Status, execution stopped. */
/* Communication link could not be established.
Please connect PC with program to be installed and start
again. */
If YES, then continue with Step 5.
If NO, then proceed to Step 6.
5.
Indications are that the ins-prog: command was not executed from a PC. A
program upgrade to the near end DDM-2000 cannot be performed with a CIT.
Use PC to repeat software download.
DDM-2000 OC-3 M
Trouble Clearing:
ULTIPLEXER
TAP-122
Page 1 of 4