NTP-005
: System Turnup
Page 2 of 4
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
2.
NOTE:
The rtrv-eqpt: command retrieves the Equipage and
Version Report. This report lists the circuit pack type
and version information for one or more slots. See the
Commands and Reports section of this manual for a
description of the rtrv-eqpt: command format.
Use the rtrv-eqpt: command to obtain the Equipage and
Version Report and verify that the service and protection (if
required) DS3 circuit packs have been installed in proper
FUNCTION UNITS group (A, B, or C) being put into service.
3.
NOTE:
The rtrv-t3: command retrieves the T3 Port
Provisioning Report. This report lists information
about each DS3 port. This information includes attributes set
by the set-t3: command. See the Commands and
Reports section of this manual for a description of the
rtrv-t3: command format.
Use the rtrv-t3: command to obtain the T3 Port
Provisioning Report and verify the software option settings.
4.
NOTE:
DS1 circuit packs cannot be installed in a group that is
equipped with DS3 circuit packs.
Verify the line build out (LBO) option jumpers are installed as
required and reinstall DS3 circuit pack(s).
5.
Make the appropriate cable connection(s) to the DS3
cross-connect point(s) or equivalent connection point(s) for the
circuit being added.
6.
Verify that no LEDs or alarms are activated. If any LEDs or alarms
are activated, refer to Trouble Clearing: IXL-001 and follow the
appropriate trouble-clearing procedure.
7.
If one of the terminating nodes is equipped with STS1E circuit
packs for an EC-1 interface to support DS3 services being
established, establish initial EC-1 low speed interface.