363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
11. Use the rtrv-state-eqpt: command to determine the port
state of the DS3 port(s) of the circuit being established.
12.
NOTE:
If a port is in the nmon (n) state, the signal is not monitored
or alarmed. The port will not automatically go to the in
service (i) state when a signal is detected as it will in the
auto (a) state. In the nmon state, the port must be returned
to the auto state, using the set-state-t3: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t3: command to set the port state of the
DS3 port(s) of the circuit being established.
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-021
Page 3 of 4