Lucent DDM-2000 OC-3 User And Service Manual page 896

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
14. If the BBF2B/BBF2C TGS or BBF4 TG3 is provisioned for sync out mode ,
refer to Table G and Figure 2 and set equalizer switches for the proper cable
length.
Table G – Equalizer Switch Settings
Equalization
0' to 131'
>131' to 262'
>262' to 393'
>393' to 524'
>524' to 655'
*
Invalid
Invalid*
Invalid*
*
If an invalid setting is selected, FAULT LED is
lighted and an alarm is generated
(unexpected CP type or
unexpected CP switches).
15.
NOTE:
Switches S1-1 and S1-2 were ignored by the system the first time the
TGS/TG3 was installed unless the timing mode was set to DS1 External
or Line Timed sync out mode . Subsequent removal or replacement of the
TGS/TG3 requires that switches S1-1 and S1-2 be set the same as the
original settings or an update upd must be performed.
Is timing mode set to either DS1 External or Line Timed sync out ?
If YES, then continue with Step 16.
If NO, then proceed to Step 17.
S2-1
S2-2
S2-3
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-523
Page 14 of 30