Lucent DDM-2000 OC-3 User And Service Manual page 160

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
8.
NOTE:
The section data communication channel (DCC), used for far
end communications, must be enabled at each network
element (shelf) optical interface being tested in order for the
end-to-end line tests to work. Default condition for the DCC
channel is "enabled". If it has been disabled, use the
set-fecom: command at each shelf to enable far end
communications.
At each shelf, use the set-fecom:address:com=enabled
command to ensure far end communications (fecom) is enabled.
9.
NOTE:
If option switch setting is changed, an update must be
performed by momentarily depressing the UPD/INIT button
on the SYSCTL after the OLIU is reinstalled.
Reinstall OLIUs (if removed) and connect each OLIU to the new
optical facility.
10.
NOTE:
Two or more shelves in the same network cannot have the
same system name or TID (set by the set-ne: command).
Verify no duplicate TID settings exist. The rtrv-ne: command
may be used at each shelf in the network to display settings. If
duplicates exist, determine new settings and use the set-ne:
command to make new settings.
11. What Release of software is installed in the system?
If Release 15 software is installed, continue with Step 12.
If Release 13 software is installed, proceed to Step 13.
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-015
Page 4 of 6