Lucent DDM-2000 OC-3 User And Service Manual page 984

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
NOTE:
If the BBF2B/BBF2C TGS or BBF4 TG3 timing mode is set to DS1
External sync out mode, an ED-8C724-20, G394 cable must be
connected to jack J37 on the shelf backplane (or J237 of the front access
cable). This cable has a relay to disconnect the incoming external timing
supply if the TGS/TG3 circuit pack is removed.
Make DS1 external timing reference connections as shown in Table A.
Table A – DS1 External Timing Reference Source Connections
Name
Receive from Primary DS1 Reference
Receive from Secondary DS1 Reference
6.
Make synchronization DS1 timing output connections as shown in Table B, if
required.
Table B – DS1 Timing Output Connections
Name
Transmit Primary DS1 Reference
Transmit Secondary DS1 Reference
!
7.
CAUTION:
A momentary transmission hit (error) will occur when the TGS circuit
pack is switched.
Is a CIT available?
If YES, then continue with Step 8.
If NO, then proceed to Step 9.
8.
Use switch-sync:s=circuitpack,pri=manual command to switch
timing to protection TGS in TIMING slot 2, if not already active.
Response:
ACTIVE LED lights on TGS circuit pack in TIMING slot 2.
DDM-2000 OC-3 M
Detailed Level Procedure:
Desig.
Conn.
T
R
P37
T
R
Desig.
Conn.
T
R
P44
T
R
ULTIPLEXER
DLP-535
Page 2 of 4
Term.
Color
6
BK
1
O
7
R
2
G
Term.
Color
6
BK
1
O
7
R
2
G

Advertisement

Table of Contents
loading

Table of Contents