Lucent DDM-2000 OC-3 User And Service Manual page 847

Tarp release 13 and later volume ii
Table of Contents

Advertisement

Table C – DDM-2000 OC-3 to OC-3 Measured Optical Power and Required LBO
Received
Transmitter
Power(dBm)
22F/22F-U/22F2-U OLIU
–8.0 to –34.0
22G-U/22G2-U/22G3-U/
22G4-U OLIU
0.0 to –3.0
–3.0 to –8.0
–8.0 to –34.0
22D-U OLIU
(Controlled &
–14.0 to –34.0
Uncontrolled Env.)
(MM Fiber Only)
Notes:
1. Measured power is defined to be the measured power of the light emitted from receive fiber connector at OLIU.
2. The minimum measured received power allows for optical path penalty and unallocated margin. Connector loss is not allotted for; it should already
be accounted for in the optical power measurement.
3. The margin for falling within the max rx power is 1.0 dB.
22F-U/22F2-U OLIU
22F OLIU
22G2-U/22G3-U OLIU
22G-U OLIU
22G4-U OLIU
LBO
Received
(dB)
Power(dBm)
0
0.0 to –34.0
10
5
0
0.0 to –34.0
0
–14.0 to –34.0
Receiver
22D-U OLIU
(Controlled Env.)
LBO
Received
LBO
(dB)
Power(dBm)
(dB)
Power(dBm)
–8.0 to –10.0
10
–8.0 to –10.0
–10.0 to –15.0
5
–10.0 to 15.0
0
–15.0 to –33.8
0
–15.0 to –31.8
0.0 to –5.0
15
–5.0 to –10.0
10
–5.0 to –10.0
–10.0 to –15.0
5
–10.0 to –15.0
0
–15.0 to –33.8
0
–15.0 to –31.8
–14.0 to –15.0
5
–14.0 to –15.0
0
–15.0 to –34.0
0
–15.0 to –31.8
22D-U OLIU
(Uncontrolled Env.)
Received
LBO
(dB)
10
5
0
0.0 to –5.0
15
10
5
0
5
0

Advertisement

Table of Contents
loading

Table of Contents