Lucent DDM-2000 OC-3 User And Service Manual page 959

Tarp release 13 and later volume ii
Table of Contents

Advertisement

DLP-532
: Detailed Level Procedure
Page 5 of 14
F.
Letter "U" in FE ID Display:
Indicates SYSCTL Switch S1 is not set properly for type of shelf being
equipped.
Remove SYSCTL. Repeat procedures of DLP-501 to correct switch
settings and to reinstall SYSCTL.
G.
Letter "E" in FE ID Display:
Indicates SYSCTL must be replaced.
Get replacement SYSCTL and repeat procedures of DLP-501.
H. Letter "F" in FE ID Display:
Indicates SYSCTL faceplate latch is not fully seated. If SYSCTL has just
been replaced, unplug SYSCTL and repeat procedures of DLP-501. If
original SYSCTL has just been unplugged and reseated, properly seat the
faceplate latch. (A reset occurs after the faceplate is seated.)
I.
Flashing Letter "L" in FE ID Display:
Indicates a low voltage condition (brownout) on the shelf.
Clear trouble using Trouble Clearing: TAP-121.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285

Advertisement

Table of Contents
loading

Table of Contents