Lucent DDM-2000 OC-3 User And Service Manual page 957

Tarp release 13 and later volume ii
Table of Contents

Advertisement

DLP-532
: Detailed Level Procedure
Page 3 of 14
NOTE:
If a linear shelf is in the STS3c mode (concat mode enabled by the
set-oc3: command) and a different software generic that does not
have the STS3c feature is loaded, the OLIUs will stay in the concat
mode until they are removed and reseated.
NOTE:
If the ins-prog: command is used for software upgrades from
non-TARP Release 9.1 or later, the software is loaded as a dormant copy
in the SYSCTL receiving the software. At the end of the download, the
rtrv-alm: report will show a status message of
dormant/exec code mismatch. The apply: command must be
used to overwrite the original executing copy of software with the new
dormant software version. See the Commands and Reports section in
Volume 1 of this manual for a description of the apply: command.
Before performing this procedure, ensure that both TGS/TG3 circuit packs are
installed in the shelf, then use the
switch-sync:s=circuitpack,pri=manual command to switch to the
protection TGS/TG3 circuit pack in TIMING slot 2, if not already ACTIVE. Use
rtrv-sync: command to verify that the protection TGS/TG3 circuit pack in
TIMING slot 2 is ACTIVE.
4.
NOTE:
If you are using a PC operating in a Windows
exit Windows and restart your PC in MS-DOS mode before performing
these download procedures. For example, if your PC is running Windows
95 you must exit Windows by clicking on the Start button, then Shut
Down, then Restart the computer in MS-DOS mode.
Obtain equipment, check software, and connect PC for download.
Reference: DLP-566
*
Registered trademark of Microsoft Corporation.
DDM-2000 OC-3 M
Issue 2, February 2000
*
environment, you must
ULTIPLEXER
363-206-285