Lucent DDM-2000 OC-3 User And Service Manual page 668

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
Table B – RTRV-ALM Message Descriptions (Continued)
Description
inhibit switch
Intersubsys com link failed
invalid CP switches
lockout of protection
Alarm
Level
ABN
MJ
CR or MN When associated with a TIMING slot, this message
ABN
DDM-2000 OC-3 M
Trouble Clearing:
Meaning
When associated with an OC-3 line, this message
means that the identified line is not selected as the
active receiving line, and a protection switch to
make this the active receiving line will not be done.
No further protection switching of specified line will
be done until the protection switch is reset. Note:
OC-3 line switching is unidirectional. Because of
this, the specified OC-3 line might still be active (if
the far end is selecting the specified line to receive
traffic), and the far end might still be free to switch
the line it is selecting to receive traffic. (See the
switch-line: command.)
When associated with a FUNCTION UNITS slot,
TIMING slot, or timing reference, this message
means that the identified equipment or reference is
not active, and protection switches to the identified
equipment or reference will not be done until the
protection switch is reset. (See the switch-fn:
and switch-sync: commands.)
*
In a MegaStar
2000 system, the SONET
subsystem session is active, but is unable to
communicate with the RADIO subsystem.
means that the timing mode switch settings on the
TGS/TG3 circuit pack are invalid.
When associated with an OC-3 line, this message
means that the identified line is not selected as the
active receiving line, and a protection switch to
make this the active receiving line will not be done.
Note: OC-3 line switching is unidirectional.
Because of this, the specified OC-3 line might still
be active (if the far end is selecting the specified
line to receive traffic), and the far end might still be
free to switch the line it is selecting to receive
traffic. The lockout will remain in effect until the
protection switch is reset or until a protection switch
inhibit request is entered. (See the switch-line:
command.)
When associated with a LOW SPEED protection
slot, this message means that no service slot in the
whole LOW SPEED GROUP will be allowed to
switch to protection. The lockout will remain in
effect until the protection switch is reset. (See the
switch-ls: command.)
ULTIPLEXER
TAP-107
Page 24 of 28