Lucent DDM-2000 OC-3 User And Service Manual page 195

Tarp release 13 and later volume ii
Table of Contents

Advertisement

NTP-020
: System Turnup
Page 7 of 8
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
20.
NOTE:
If a port is in the nmon (n) state, the signal is not monitored
or alarmed. The port will not automatically go to the in
service (i) state when a signal is detected as it will in the
auto (a) state. In the nmon state, the port must be returned
to the auto state, using the set-state-t3: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t3: command to set the port state of the
DS3 port of the circuit being established.
21. Use the set-t1: command to set the characteristics of the DS1
port(s) of the circuit being established.
22. Use the rtrv-state-eqpt: command to determine the port
state of the DS1 port(s) of the circuit being established.
23.
NOTE:
If a port is in the nmon (n) state, the signal is not monitored
or alarmed. The port will not automatically go to the in
service (i) state when a signal is detected as it will in the
auto (a) state. In the nmon state, the port must be returned
to the auto state, using the set-state-t1: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t1: command to set the port state of the
DS1 port(s) of the circuit being established.
24. If BBF3/BBF3B DS1PM circuit packs are installed and the
optional ds1pm performance monitoring feature is to be used, use
the set-feat:feat=ds1pm,act=enable command to enable
the feature.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285