NTP-028
: System Turnup
Page 3 of 6
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
7.
NOTE:
The rtrv-t1: command retrieves the T1 Port
Provisioning Report. This report lists information
about each IMA LAN port. This information includes
attributes set by the set-t1: command. See the
Commands and Reports section of this manual for a
description of the rtrv-t1: command format.
At each LAN terminating node, use the rtrv-t1: command to
obtain the T1 Port Provisioning Report and verify the
hardware and software option settings.
8.
Install 177A Retainer Cards into all unused service slots.
9.
At each LAN terminating node, use the set-t1: and set-lan:
command to set the characteristics of the LAN port and protocols
of the circuit being established. See the Commands and Reports
section of Volume I of this manual for an explanation of these
commands.
10. At each LAN terminating node, make the appropriate cable
connection(s) to the DS1/DS3 cross-connect point(s) or
equivalent connection points for the circuit being established.
11. Verify that no LEDs or alarms are activated. If any LEDs or alarms
are activated, refer to Trouble Clearing: IXL-001 and follow the
appropriate trouble-clearing procedure.
12. If one of the terminating ends is equipped with DS1 or TMUX
circuit packs for a DS1 or DS3 interface to support services being
established, establish initial DS1 (NTP-004) or DS3-to-DS1
(NTP-020) service.