Lucent DDM-2000 OC-3 User And Service Manual page 884

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
Table A – Circuit Pack Replacement (Contd)
Circuit Pack
BBF3/BBF3B DS1PM
BBF5 JMPR
BBG6 STS1E
BBF8 HDSL
BBF6 T1EXT
BBF9/BBF10 LAN
BBG8/BBG8B SYSCTL
2.
Refer to DLP-501 to replace the SYSCTL.
3.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
BBG2/BBG2B MXRVO
!
4.
CAUTION:
To prevent errors, use the sw-fn:address:pri=manual command to
switch service to the standby slot before removing the MXRVO circuit
pack being replaced.
There are no options to be set on the BBG2/BBG2B MXRVO circuit pack.
Remove old MXRVO and install replacement MXRVO.
Response:
5.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
Step
Step 34
Step 39
Step 41
Step 47
Step 51
Step 55
FAULT LED on the MXRVO lights for about 13 seconds
and then goes off.
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-523
Page 2 of 30

Advertisement

Table of Contents
loading