Lucent DDM-2000 OC-3 User And Service Manual page 889

Tarp release 13 and later volume ii
Table of Contents

Advertisement

DLP-523
: Detailed Level Procedure
Page 7 of 30
9.
NOTE:
Switches S1-1 and S1-2 were ignored by the system the first time the
TGS was installed unless the timing mode was set to DS1 External .
Subsequent removal or replacement of the TGS requires that switches
S1-1 and S1-2 be set the same as the original settings or an update upd
must be performed.
Is timing mode set to DS1 External ?
If YES, then continue with Step 10.
If NO, then proceed to Step 11.
10. Refer to Table D and Figure 1 and set the DS1 line coding and frame format as
required for the TGS circuit pack.
Table D – TGS DS1 Line Coding and Frame Format Switch Settings
DS1 Line Code
AMI
B8ZS
!
11.
CAUTION:
When all OC-3 shelves in a bay are timed from a common external timing
supply, removal of the bottom shelf TGS circuit pack will cause a
momentary transmission hit on all shelves in the bay.
NOTE:
A TGS circuit pack is required in TIMING slot 1 to protect against
accidentally downloading wrong software and interrupting transmission.
Transmission configuration information is stored in the TGS circuit pack in
TIMING slot 1. During software download procedures the software
checks the information stored in the TGS 1 circuit pack. If the information
is incompatible with the controller software information, an alarm is
generated.
NOTE:
If a signal has previously been applied to the original TGS circuit pack,
the FAULT lamp will flash when the new TGS is installed until the signal
tests good.
Remove old TGS and install replacement TGS.
Response:
12. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
Switch
S1-1
DS1 Frame Format
ON
SF
OFF
ESF
FAULT LED on the TGS lights (flashes) for about 15
seconds and then goes off.
DDM-2000 OC-3 M
Issue 2, February 2000
Switch
S1-2
ON
OFF
ULTIPLEXER
363-206-285