DLP-521
: Detailed Level Procedure
Page 3 of 4
6.
If security has been enabled, enter your login, and then enter your password
when prompted.
If security has not been enabled, enter a carriage RETURN.
Response:
7.
NOTE:
The system prompt may be something other than < if there is an alarm
condition (for example, if there is an MJ alarm condition on the system,
the prompt will be MJ <).
NOTE:
After the prompt (<), the system will respond to commands entered. The
command set-link:pg=( ) may be used to set the vertical size of the
displayed page on the CIT. Page (pg) length may be set from 3 to 150
lines with a default length of 24 lines. The page length is set to default
each time a new CIT session is started.
See the "Commands and Reports" section of this manual for a description of
the command formats.
8.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
CIT prints the following message followed by an alarm
and status report:
/*************************************
*
*
Lucent Technologies
*
DDM-2000 OC-3 Multiplexer
*
*
Release a.b.c
*
*************************************/
TID date time
M
rtrv-alm:all COMPLD
/* Active Alarms and Status Report
DDM-2000 OC-3 M
Issue 2, February 2000
.
.
.