DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
32.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple areas require that the NSAPAREA field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3:
command be set. See Section 11, Commands and Reports
in 363-206-285, DDM-2000 OC-3 Multiplexer, TARP Release
13 and Later, User/Service Manual —Volume I , for an
explanation of the command parameters and 824-102-144,
Lucent Technologies 2000 Product Family, Operations
Interworking Guide For TARP Releases , for an explanation
of the engineering rules for subnetwork partitioning.
Use the ent-ulsdcc-l3: command to designate the
NSAPAREA field and level 2 IS-IS routing, as required.
33.
NOTE:
If Kbyte or Sbyte (sync messaging) is enabled for the
main-1 and main-2 optical interfaces at any node in a ring,
it must be enabled at all nodes of the ring.
NOTE:
The rtrv-oc3: command retrieves the
OC-3 Line Provisioning Report. This report displays
the provisioned configuration of OC-3 lines. See the
Commands and Reports section of this manual for a
description of the rtrv-oc3: command format.
Use the rtrv-oc3: command to obtain the
OC-3 Line Provisioning Report and verify if Kbyte/Sbyte
is enabled or disabled. Use the set-oc3: command to enable or
disable the Kbyte/Sbyte parameter, as required.
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-029
Page 21 of 22