Lucent DDM-2000 OC-3 User And Service Manual page 94

Tarp release 13 and later volume ii
Table of Contents

Advertisement

NTP-002
: System Turnup
Page 2 of 2
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
2.
Use the rtrv-oc3/set-oc3 command at the DDM-2000
OC-12/3 shelf to verify/set application (app) parameter for
FUNCTION UNITS C slots being used for OC-3c service. For
example, set-oc3:app=0X1.
3.
Use the ent-crs-sts3c: command at each shelf to make the
following STS-3c cross-connections: m-1 to c-1. For example,
ent-crs-sts3c:m-1,c-1.
4.
Determine the optical loss of the OC-3c span from the DDM-2000
to the broadband terminating equipment.
5.
Remove optical loops from OLIUs in FUNCTION UNITS C slots
and the broadband terminating equipment.
6.
Connect the optical cables from the DDM-2000 OC-3 FUNCTION
UNITS C slots to the broadband terminating equipment.
7.
Perform an OC-3c transmission test using a SONET test set, if
required.
DDM-2000 OC-3 M
Issue 3, June 2001
ULTIPLEXER
363-206-285
DLP-544