Lucent DDM-2000 OC-3 User And Service Manual page 132

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
13. Determine the necessary STS-1 cross-connections for each node
from the work order of circuit order.
14. As required, at each shelf in the end-to-end network, use the
ent-crs-sts1: command at each shelf to make required
STS-1 cross-connections for DS3 channel being established.
A. Ring Configuration
B. Dual Ring Interworking (DRI) Configuration
C. Single/Dual OC-3/OC-48 Configuration
D. Single/Dual OC-3/OC-12 Configuration
15. Perform an end-to-end DS3 low-speed transmission test for each
DS3 group being put into service (optional).
A. Single Ring Configuration
B. Dual Ring Interworking (DRI) Configuration
C. Single/Dual Homing Configuration
16. Use the set-t3: command to set the characteristics of the DS3
port.
17. Use the rtrv-state-eqpt: command to determine the port
state of the DS3 port(s) of the circuit being established.
18.
NOTE:
If a port is in the nmon (n) state, the signal is not monitored
or alarmed. The port will not automatically go to the in
service (i) state when a signal is detected as it will in the
auto (a) state. In the nmon state, the port must be returned
to the auto state, using the set-state-t3: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
Use the set-state-t3: command to set the port state of the
DS3 port(s) of the circuit being established.
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-009
Page 4 of 4
DLP-546
DLP-550
DLP-559
DLP-560
DLP-511
DLP-553
DLP-511