363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
NOTE:
The following commands may be used to convert, delete,
enter, and retrieve cross-connections: cnvt-crs,
dlt-crs-vt1, dlt-crs-sts1, ent-crs-vt1,
ent-crs-sts1, rtrv-crs-vt1, and rtrv-crs-sts1.
See the Commands and Reports section of this manual for a
description of commands. See Cross-Connection
Provisioning in the Administration and Provisioning section
of this manual for more information on cross-connections.
NOTE:
If the cross-connection to a group with a DS1 being
discontinued is an STS1 cross-connection, removal of the
STS1 cross-connection may cause service interruption to
other DS1 circuit packs. In order to remove an individual
DS1, the cnvt-crs may have to be used to convert the
STS1 cross-connection to 28 individual VT1.5
cross-connections. If the entire group is being discontinued,
the STS1 cross-connection may be removed, if required.
Use the dlt-crs-vt1: command to delete the terminating
(drop) node cross-connections for all DS1 service being removed,
if required.
7.
Use the dlt-crs-vt1: command to delete the pass-through
cross-connections at each nonterminating node for all DS1
service being removed, if required.
8.
If all four DS1 ports on the DS1/DS1PM circuit pack are being
discontinued, you may remove the DS1/DS1PM circuit pack, if
required.
9.
If all DS1/DS1PM circuit packs in a group are removed, you may
remove the group function unit (MXRVO or STS1E) circuit packs
and the protection DS1/DS1PM circuit pack, if required.
10. If group MXRVO/STS1E circuit packs are removed, proceed to
Step 12. Otherwise, continue with Step 11.