363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
3.
On STS-1 path-switched rings, all nodes in the ring
must be provisioned as STS-1 cross-connections.
NOTE:
The following commands may be used to convert, delete,
enter, and retrieve cross-connections: cnvt-crs,
dlt-crs-sts1, dlt-crs-vt1, ent-crs-sts1,
ent-crs-vt1, rtrv-crs-sts1, and rtrv-crs-vt1.
See the Commands and Reports section of this manual for a
description of commands. See Cross-Connection
Provisioning in the Administration and Provisioning section
of this manual for more information on cross-connection
provisioning.
Determine the necessary cross-connections for each node from
the work order or office records.
10. Make necessary VT1.5/STS1 cross-connections for each node.
A. Single OC-3 Ring Configuration
B. Dual Ring Interworking (DRI) Configuration
C. Single/Dual OC-3/FiberReach Configuration
D. Stand Alone OC-3/FiberReach Configuration
E. Single/Dual OC-3/OC-48 Configuration
F.
Single/Dual OC-3/OC-12 Configuration
11. Perform the appropriate end-to-end transmission test for circuit
being put into service. For a circuit in a path protected ring
network, use the sw-path-( ):address command at both
terminating nodes to switch the active path and repeat this test on
the other path.
A. DS1 Single OC-3 Ring Test
B. DS1 Dual Ring (DRI) Test
C. DS3 Single OC-3 Ring Test
D. DS3 Dual Ring (DRI) Test
E. DS1 Single/Dual Homing Test
F.
DS3 Single/Dual Homing Test
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-035
Page 3 of 4
DLP-546
DLP-550
DLP-557
DLP-558
DLP-559
DLP-560
DLP-510
DLP-554
DLP-511
DLP-553
DLP-510
DLP-511