Hicom 150 E Office Rel.1.0 Service Manual - 3.2 Central boards
Battery manager: S30122-K5083-L302 or S30122-K5083-X302
Battery set: S30122-X5083-X303
Distribution frame (for connecting an existing external battery):
C39165-A7200-B10
Technical data for the USVI
PSUI in normal mode
- Input voltage (from PSUI): approx. 380 VDC/max. 0.27 A)
- Output voltage (charging voltage for batteries): 54 or 55.2 VDC (max. 1.6 A)
Power failure mode
- Input voltage (from battery): 42 V - 56 VDC
- Output voltage (to PSUI): approx. 340 VDC (max. 1.1 A)
Battery set capacity (battery set rating): 12 Ah (battery set with 7 Ah in planning)
Bridging time
Front and rear view of the USVI, settings