Hicom 150 E Office Rel.1.0 Service Manual -
6.2.2.10 Administration
LAN Bridge administration is also described in the "LAN Bridge card" administrator manual,
(reference number A31003-K16-B627-*-19, LZF Fürth).
Calling up the service tool
The password-protected menu service can be called up for more intensive diagnostics.
Activation: press the keys CTRL and Q and enter the name of the service technician and the service
code 17197.
(Important: the service code can be changed.) A supplementary menu (Service) then appears.
Receiving and saving trace data
The contents of the trace memory of a HICOM system can be loaded to the maintenance computer
and stored as ASCII text under any file name. The trace data can be evaluated using any editor or text
program. If a Hicom system was not yet selected, the user is prompted to select one now. If not
already entered, the customer password must be specified to load trace data.
Receiving and saving the error memory
The error memory of a HICOM system can be transferred here to the maintenance PC and saved there
as an ASCII file. If a Hicom system was not yet selected, the user is prompted to select one now. If
not already entered, the customer password must be specified to load trace data.
Receiving and saving a memory area
A memory dump from the HICOM system can be transferred here to the maintenance PC and saved
there as an ASCII file. The user must also specify the start address (hexadecimal) and number of bytes
to be transferred (decimal). If a Hicom system was not yet selected, the user is prompted to select one
now. If not already entered, the customer password must be specified to load trace data.
Deleting the trace memory
The trace buffer of a HICOM system can be deleted with this command. If not already entered, the
customer password must be specified to load trace data.
Deleting the error memory
The error memory of a HICOM system can be deleted with this command. If not already entered, the
customer password must be specified to load trace data.
Preparing the upload of new Assistant software
The system must be reset before you can add new firmware to the HICOM system. This is triggered
with this command The customer and service passwords are both required for this procedure. The
actual firmware transfer must then be performed via the V.24 interface with the Siemens upload tool.
Changing the number of released B channels
The number of released B channels can only be changed with the help of the service password.
Changing the service password