Table 3-16 Slmo8/Slmo24 - Led State; Table 3-17 Slmo8 / Slmo24 - Cable 1 Assignment (Su X8) - Siemens Hicom 150 E Office Service Manual

Hide thumbs Also See for Hicom 150 E Office:
Table of Contents

Advertisement

Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards
Figure 3-17 SLMO8 / SLMO24 (S30810-Q2901-X / S30810-Q2901-Xxxx)
LED states and their meaning
Red LED Green LED
Off
Off
On
Off
Flashing
Off
Off
On
Off
Flashing
Cable and SU connector assignment (backplane)

Table 3-17 SLMO8 / SLMO24 - cable 1 assignment (SU X8)

Colour
Pair a-wire b-wire SU conn.
group
1
1
wht/blu
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (8 of 46) [06/04/2000 13:03:52]

Table 3-16 SLMO8/SLMO24 - LED state

State
Board not receiving power / is not
plugged in correctly.
Board is deactivated.
Board is receiving power / board test in
program.
Board is defective if state remains
unchanged (i.e. board test unsuccessful).
Loadware loading operation was not
successfully completed. Board is
defective.
Error was detected on board. Board is
deactivated (does not apply to errors
detected by test loops) / board was
deactivated by means of Hicom Assistant
E.
Loadware is being loaded.
Loadware operation was successfully
completed / board is operational (idle
state).
At least one extension is activated.
BP: X8
19
blu/wht
39
SLMO8
Notes
SLMO24
1a
Access 1
1b
Action
Check plug contact on board.
Replace board.
Replace board.
Check whether board was
deactivated by Hicom Assistant
E. If not, replace board.