Hicom 150 E Office Rel.1.0 Service Manual - 8.15 CorNet networking
Line 4: Dialled digit 3-XX reference route table 2 (plan for CorNet - extensions 300 - 399)
Line 5: Dialled digit 4-XX reference route table 2 (plan for CorNet - extensions 400 - 499)
Make the following entries in relevant columns in the Route table window:
Table 1, line 1: Route 1, Dial rule 1, Warning: NONE (table for trunk call)
Table 2, line 1: Route 1, Dial rule 2, Warning: NONE (table for CorNet call)
Make the following entries in the Dialling rules table:
Line 1: Rule name: Trunk, Rule format: D77A, Procedure: Corporate network
Line 1: Rule name: Master system, Rule format: E1A, Procedure: Corporate network
Closed numbering without LCR and without break out
Prerequisites for programming example
The master system contains the extension numbers 100 - 499, while the slave system contains the
numbers 500 - 699.
Both system have an ISDN trunk connection with attendant code 0 (e.g. route 1 with code 0)
Both systems have a CorNet link to the remote system (route 2 in master system, route 1 in slave
system)
Break out is not possible in the remote system.
Programming the master system via Assistant E
Go to Routes in the Lines/networking window and select Route 2. Make the following settings:
Enter the route name, the trunk group code for route 2 must be set to 5 and 6.
The route type is set to PABX in the Routing parameters window, Digit repetition on is activated
and the route telephone number (PABX number) is set under No. and type, outgoing.
The CorNet lines are to be assigned to Route 2 in the Trunks window. Double-click on the asterisk in
the Param column for relevant the line to set the parameter to S0: CorNet-N variant 2 master (direct).
In the System Parameters window, ensure that the call number of the external attendant code is set to
0 in the Diversion/VPL tab. Deactivate Automatic line seizure in the Flags/CMI tab!
Programming the slave system via Assistant E
Go to Routes in the Lines/networking menu and select Route 2. Make the following settings:
Enter the route name, the trunk group codes for route 2 must be set to 1, 2, 3 and 4.
The route type is set to PABX in the Routing parameters window, Digit repetition on is activated
and the route telephone number (PABX number) is set under No. and type, outgoing.
The CorNet lines are to be assigned to route 2 in the Trunks window. Double-click on the asterisk in
the Param column for the relevant line to set the protocol to S0: CorNet-N variant 2 slave (direct).
In the System Parameters window, ensure that the call number of the external attendant code is set to
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_815.htm (5 of 13) [06/04/2000 13:12:59]