Hicom 150 E Office Rel.1.0 Service Manual - 7.3 Features for general outgoing traffic
Dependencies/Limitations
Subject
Extension trunk access While the code lock is activated, the extension trunk access is set to a class
Code lock
Configuration options
This feature does not have to be explicitly configured.
Performing Feature Check
Check the feature for error-free functioning as follows:
Step
1.
Lock the telephone (e.g. code + PIN)
*66 + PIN (default = 00000).
2.
Change PIN
*93 + old code + new code + new code.
3.
It is not possible to place external calls.

7.3.3 System Code Lock/COS Changeover

Definition
An authorised user can activate the code lock for an internal extension.
This has the same effect on the terminal as the individual code lock. The code lock can be deactivated
from the attendant console or the extension.
You can continue to use system speed-dialling while the code lock is active.
Model-Specific Data
Subject
Feature available in
HW requirements
SW requirements
Dependencies/Limitations
Subject
Extension trunk access While the code lock is activated, the extension trunk access is reduced to a
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_73.htm (3 of 6) [06/04/2000 13:10:06]
of service that is configured system-wide (default=1).
While the code lock is activated, you cannot activate any features which
could incur costs for the subscriber. Exceptions are: speed-dialling,
babyphone, voice calling and conferences with internal extensions.
Action
OfficePro
OfficeCom
x
-
As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
class of service that is configured system-wide (default=1).
Dependency/Limitation
OfficePoint
x
x
-
-
Dependency/Limitation
OfficeOne
x
-