Configuring An Isdn System Interface - Siemens Hicom 150 E Office Service Manual

Hide thumbs Also See for Hicom 150 E Office:
Table of Contents

Advertisement

Hicom 150 E Office Rel.1.0 Service Manual - 8.8 Configuring an ISDN system interface

8.8 Configuring an ISDN system interface

Introduction
Enter the system extension number without prefix and without attendant code.
DID is not possible without a system extension number!
The system extension number must be entered for each route.
Example
Country: 49
Prefix: 02302
System extension number: 4711-0
Programming with Hicom Assistant T
Step
Entry
1.
*95 31994 Start system administration
2.
20-2
3.
1
4.
* 4711
5.
F2
6.
* 2302
7.
F2
8.
* 49
9.
F8 F7
Programming with Hicom Assistant E
Step
1.
Options -> Lines / networking -> Routes
|
Siemens
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_88.htm [06/04/2000 13:12:32]
Action
Select the route telephone number Route tel. number
Select the local no.
Enter the local number
Go to: National No.
Enter the national number
Go to: International No.
Enter the international number
Exit system administration