Siemens Hicom 150 E Office Service Manual page 414

Hide thumbs Also See for Hicom 150 E Office:
Table of Contents

Advertisement

Hicom 150 E Office Rel.1.0 Service Manual - 7.2 Features for general incoming traffic
Subject
Feature available in
HW requirements
SW requirements
No. of CFW operations that can be
activated simultaneously
Dependencies/Limitations
Subject
Do not disturb
Call forwarding
Ext. call forwarding
Ext. call forwarding
Prime Line
Analog terminals
Timed reminder, automatic
wake-up system
Configuration options
This feature does not have to be explicitly configured.
Performing Feature Check
Check the feature for error-free functioning as follows:
Step
1.
Activate call forwarding (*1).
2.
Select type (1 = all calls, 2 = external calls only, 3 = internal calls only).
3.
Call the terminal.
4.
The call should arrive at the destination extension according to the call forwarding type
activated (all calls, external calls only or internal calls only).
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_72.htm (11 of 48) [06/04/2000 13:09:57]
OfficePro
x
-
As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
150
CFW cannot be programmed on a terminal where do not disturb is
activated.
CFW chaining is not possible.
Only one external CFW destination can be programmed under a key
on each terminal.
When dialling external destinations, the destination number must be
prefixed by the CO route code.
If Prime Line on (automatic line seizure) is active, you must press
the extension key before entering the extension number when
dialling internal destinations. In this case, the route code for external
destinations is not necessary.
When using a/b, S
0
confirmation tone after entering external destinations.
If a timed reminder is pending, it does not follow an activated CFW.
Action
OfficeCom
x
-
50
Dependency/Limitation
and CMI terminals, you must wait for a
OfficePoint
OfficeOne
x
-
20
x
-
20