Hicom 150 E Office Rel.1.0 Service Manual - 7.12 Features for Call Detail Recording
7.12 Features for Call Detail Recording
7.12.1 Silent Reversal at Start and End of Call
Definition
In many countries, a "silent reversal" is used on loop start trunks to record the start and end of an
outgoing call. These criteria are used for time recording within central call detail recording. This is
especially necessary when an exact settlement of call charges is required (e.g. hotel).
The feature can be set for each circuit.
Model-Specific Data
Subject
Feature available in
HW requirements
SW requirements
General requirements Loop start trunk
Dependencies/Limitations
Subject
Silent Reversal In countries which do not signal silent reversal at the end of a call, the duration of
the call is determined by hanging up the A extension.
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step
1.
Configure silent reversal for each trunk line
*9531994
2.
21-6 => Analogue Parameters - Silent-Reversal
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_712.htm (1 of 21) [06/04/2000 13:08:17]
OfficePro
OfficeCom OfficePoint OfficeOne
x
TML8W
+
GEE8
As of Rel. 1.0
Action
-
-
-
-
-
-
-
-
Dependency/Limitation
-
-
-
-