8.6 Configuring toll restriction per extension

Introduction
For each extension, 15 levels of toll restriction are available:
0 = No toll restriction *)
1 = Only incoming calls are permitted. *)
2-7 = Only the digits entered in allowed lists 1 to 6 can be dialled. *)
8-13 = Digits entered in barred lists 1 to 6 cannot be dialled. *)
14 = Full access, no restrictions
*) System speed-dialling destinations can be dialled without restriction.
Allowed number list:
One allowed list (allowed list 1) with 45 positions
5 additional allowed lists (allowed lists 2 to 6) with 10 positions each
Class of service 2 corresponds to allowed list 1, class of service 3 corresponds to allowed list 2, etc.
Example
The extension with extension number 250 is in class of service 2 and during the day can access only
the emergency numbers (110 and 112) via lines 1 and 2.
Programming with Hicom Assistant T
Step
Entry
1.
*95 31994 Start system administration
2.
15-1
3.
# 250
4.
* 2
5.
2
6.
+ * 2
7.
F7
8.
3-1
9.
* 110
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_86.htm (1 of 2) [06/04/2000 13:12:25]
Action
Trunk access, day
Select extension 250
Enter new data
Allowed list 1 for line 1
Allowed list 1 for line 2
Return to Call Barring Menu Call Barring Menu
Select allowed list 1
Enter extension number 110 Pos 1: 110
Display
System Administration
Ext 200, Trk 1: full
Ext 250: as for ext 200
Ext 250, Trk 1:
Ext 250, Trk 1: E-L 1
Ext 250, Trk 1: E-L 1
Pos 1: -