End-Of-Dialling Recognition - Siemens Hicom 150 E Office Service Manual

Hide thumbs Also See for Hicom 150 E Office:
Table of Contents

Advertisement

Hicom 150 E Office Rel.1.0 Service Manual - 7.6 Features for outgoing external traffic
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step
1.
Configure audible tone monitoring
*9531994
2.
21-2 => Analogue Parameters - Dial Pause
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step
1.
Configure audible tone monitoring
Options
2.
Lines / networking
3.
Routing parameters (`Digit request with loop start' and `Analysis of second dial tone')
4.
Set times
Options
5.
System Parameters
6.
Time parameters (`Dial tone monitoring time' and `Time between HT analysis and dialling of
trunk main station in').
Performing Feature Check
Check the feature for error-free functioning as follows:
Step
1.
Configure dial pause.
2.
The digits are only transmitted when the pause has elapsed.

7.6.8 End-of-Dialling Recognition

Definition
As in the case of en-bloc dialling, the end of dialling is signalled either automatically after the timer
expires or manually by the user by means of the end-of-dialling code "#".
Model-Specific Data
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_76.htm (10 of 21) [06/04/2000 13:10:46]