Hicom 150 E Office Rel.1.0 Service Manual - 4 Installation
Figure 4-4 Hicom 150 E OfficePro - installation of a two-cabinet system (side by side)
Laying the connecting cables
Remove the lower grills in the rear covers to lay the connecting cables between the cabinets.

4.1.6.6 Setting up a three-cabinet system (stacked)

Caution
A maximum of two cabinets only may be stacked.
Procedure
Step
1.
Remove the front and rear
2.
Mount one
base element
next to the BC in the installation site and make sure that they are level and stable. Correct any
differences in height.
3.
Place expansion cabinet EC1 on the basic cabinet. Insert the feet of EC1 into the appropriate
depressions in the top of the BC.
4.
Attach the three cabinets using four connecting plates and two screws with washers each
(Figure
4-5).
It is important to ensure that the connecting plates are mounted in the correct direction (facing
inside!).
Installing a three-cabinet system
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_4m.htm (8 of 27) [06/04/2000 13:04:41]
Action
cabinet
covers.
each on the basic cabinet and expansion cabinet (EC2). Place EC2

Advertisement