Hicom 150 E Office Rel.1.0 Service Manual -
5.2 Start-up of Hicom 150 E OfficeCom,
OfficePoint, OfficeOne
5.2.1 Overview
Chapter contents
This chapter contains information on how to start up the Hicom 150 E
OfficeCom/OfficePoint/OfficeOne communication system.
Danger
Only authorized service personnel should carry out the system start-up.

5.2.2 Start-up procedure

1. Set up the desired system configuration (insert all required boards).
2. Connect and screw in the PSU/UPS, plug in the power cable of the power supply unit.
3. The system is ready when the date "SAT 1 JAN 00" and the time "00.00" appear in the system
telephone's display.
4. Carry out
country
5. Enter the
route telephone
6. Program the system using either the programming telephone with "ASSISTANT T" or the
"Assistant E" PC tool.
7. Carry out a
quick
Changes to the system (programming telephone, key programming) made during an offline
programming session will be lost when data is read back to the PC.
OfficeCom/OfficePoint LED status display
The CBFC central board is equipped with two green LEDs that indicate the status of the board (H9)
and of the integrated analog modem (H10).
CBFC status display
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_5fc.htm (1 of 9) [06/04/2000 13:07:42]