Hicom 150 E Office Rel.1.0 Service Manual - 8.3 Displaying an incoming call as a company name
A free extension must be available in order for an extension name to be assigned (if possible, an
extension should be selected that does not exist at the hardware level).
This extension must be configured as an answering machine.
The extension must be assigned to a free index in call management with an initial entry of "*"
in order for the extension name to be forwarded. The second entry contains the number of the
extension that is to be called with the extension name entered (this entry can also be a group).
Example
The DID number 250 is assigned to Siemens, for example.
The extension with extension number 200 is to be called using both visual and audible signals.
Programming with Hicom Assistant T
Step
Entry
1.
*95 31994 Start system administration
2.
14-11
Display the "Extension Type" menu
3.
#
Initiate extension selection
4.
250
Select extension 250
5.
Confirm selection of extension 250
6.
*
Change extension type
7.
4
Answering machine extension type
8.
Confirm entry
9.
F7
Return to: Extension Data Menu
10.
12
Extension names
11.
#
Initiate extension selection
12.
250
Select extension 250
13.
Confirm selection of extension 250
14.
*
Change extension name
15.
Siemens Enter "Siemens" as the extension name
16.
Confirm extension name
17.
F8
Return to main menu
18.
16
Initiate selection of "Call Management Inc" Call Management Inc
19.
18
Select "CM-Elements".
20.
1
Initiate selection of "CM-Target 1"
21.
+
Select "Next"
22.
*
Select "Change entry"
23.
200
Select extension 200
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_83.htm (2 of 3) [06/04/2000 13:12:18]
Action
Display
System Administration
Ext 200: Auto-select
Ext:
Ext: 250
Ext 250: Auto-select
Ext 250:
Ext 250: Answer m/c
Ext 250: Answer m/c
Extension Data Menu
Ext 200: -
Ext:
Ext: 250
Ext 250: -
Ext 250:
Ext 250: Siemens
Ext 250: Siemens
System Administration
CM-Elements
List 1, Mbr 1: call
List 1, Mbr 2: -
List 1, Mbr 2:
List 1, Mbr 2: 200