Hicom 150 E Office Rel.1.0 Service Manual - 7.13 Euro-ISDN features
Missed called lists and Smartset can therefore also be implemented when using carriers for answering
calls. The available prefixes are also used for the carriers.
Model-Specific Data
Subject
Feature available in
HW requirements
SW requirements
CO feature
Extension feature
Dependencies/Limitations
Subject
National or international prefix There is only one national or one international prefix system-wide.
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step
1.
Set codes
*9531994
2.
20-2-5 => ISDN Parameter Menu - Route tel. number - National Prefix
3.
20-2-6 => ISDN Parameter Menu - Route tel. number - Internat. Prefix
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step
1.
Set codes
Options
2.
Lines / networking
3.
ISDN parameters
4.
Enter national/international prefix
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_713.htm (15 of 16) [06/04/2000 13:11:54]
OfficePro
OfficeCom
x
S
As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
-
x
These and therefore the codes for carriers can be set as 2-digit
codes.
Action
Action
OfficePoint
x
x
module
0
-
-
x
x
Dependency/Limitation
OfficeOne
x
-
-
x

Advertisement

Table of Contents
loading

Table of Contents