Hicom 150 E Office Rel.1.0 Service Manual - 8.14 Configuring an intercept extension per line
8.14 Configuring an intercept extension per line
Introduction
In the case of systems with different basic accesses, it may be necessary to configure a separate
intercept position for each basic access. This is performed by means of call allocation per line.
If a number of intercept position are configured, the intercept position (day and night) must
be cancelled. An undialled line cannot be switched.
Example
Lines 1 and 2 (1st S
Lines 3 and 4 (2nd S
Programming with Hicom Assistant T
Step
Entry
1.
*95 31994 Start system administration System Administration
2.
16-12
3.
*
4.
F2
5.
*
6.
F7 16
7.
+ +
8.
* 300
9.
+ * 300
10.
F7 17
11.
+ +
12.
* 300
13.
+ * 300
14.
F8-F7
Programming with Hicom Assistant E
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_814.htm (1 of 2) [06/04/2000 13:12:51]
basic access) are to be allocated to extension 200.
0
basic access) are to be allocated to extension 300.
0
Action
Select Intercept, Day
Delete Intercept, Day
Select Intercept, Night
Delete Intercept, Night
Select Non DID,Day
Select trunk 3
Enter station 300
Enter station 300
Select Non DID,Night
Select trunk 3
Enter station 300
Enter station 300
Exit system administration Set time, Set date
Display
Call No.: 200
Call No.: -
Call No.: 200
Call No.: -
Trk 1: 200
Trk 3: 200
Trk 3: 300
Trk 4: 300
Trk 1: 200
Trk 3: 200
Trk 3: 300
Trk 4: 300