Hicom 150 E Office Rel.1.0 Service Manual - 8.15 CorNet networking
slave system taking into consideration the trunk code of the master system.)
Network-wide toll restriction implemented via LCR restriction
Note
If toll restriction is performed via the LCR restriction, the system speed-dialling numbers are also
subject to this toll restriction. In other words, an outward-restricted station cannot dial a system
speed-dialling number!
Prerequisites for programming example
Internal access: internal access can be implemented by means of TRG groups (not described here)
Outward-restricted trunk access is LCR toll restriction 2, extension 150 is assigned this restriction.
Restricted local access is LCR toll restriction 3, extension 140 is assigned this restriction (the prefixes
023Z may be dialled).
Unrestricted local area access is LCR toll restriction 4, extension 130 is assigned this restriction (the
prefixes 02Z and 03Z may be dialled).
National trunk access is LCR toll restriction 5, extension 120 is assigned this restriction.
European trunk access is LCR toll restriction 6, extension 110 is assigned this restriction (the prefixes
004Z may be dialled).
Unrestricted trunk access is LCR toll restriction 15, extension 100 is assigned this restriction.
Programming
Go to the window Least cost routing/Codes and flags and activate Release LCR.
Switch to the window Least cost routing/Classes of service and assign the appropriate toll
restrictions to extensions 100 to 160.
Switch to the window Least cost routing/Dial plan and make the following entries:
Line 1: Dialled digits: 0CZ, Route table: 1 (unrestricted trunk access)
Line 2: Dialled digits: 0C004Z, Route table: 2 (European trunk access)
Line 3: Dialled digits: 0C0Z, Route table: 3 (national trunk access)
Line 4: Dialled digits: 0C02Z, Route table: 4 (unrestricted local area access)
Line 5: Dialled digits: 0C03Z, Route table: 4 (unrestricted local area access)
Line 6: Dialled digits: 0CNZ, Route table: 5 (restricted local access)
Line 7: Dialled digits: 0C1Z, Route table: 5 (restricted local access)
Line 8: Dialled digits: NZ, Route table: 6 (outward-restricted trunk access)
Line 9: Dialled digits: 1Z, Route table: 6 (outward-restricted trunk access))
Switch to the window Least cost routing/Route table and make the following entries:
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_815.htm (10 of 13) [06/04/2000 13:12:59]