Hicom 150 E Office Rel.1.0 Service Manual - 8.27 Configuring Hicom cordless 150 E

8.27 Configuring Hicom cordless 150 E

Introduction
Sixteen handsets are automatically released for use by inserting the SLMC8 board in Hicom 150 E
OfficePro.
The process for programming names, etc. is the same as for normal extensions.
The startup operation is restricted to logging in the handset with the code generated by the system.
Other handsets are put into operation with a code and a release procedure.
Note
The CGM module must be inserted when using Hicom cordless 150 E. A high level of clock precision
is required in this case.
Login procedure
Deactivate the handsets to be logged in (in this case, handset 1 with code: 11568 and RNR:
124).
Open the Hicom 150 E OfficePro login window. This remains open for 10 minutes. The
handset must be logged in within this period of time.
The login window stays open for another 10 minutes following successful login.
Entry
*94 2 19970707 Open the login window Ready
Check the PIN code generated by the system and the call number.
Programming with Hicom Assistant T
Step
Entry
1.
*95 31994 Start system administration
2.
36
Set the Hicom cordless 150 E setting
3.
2
Check the PIN code for the 1st handset
4.
F2
Check the call number for the 1st handset Device 1: 124
5.
F8-F7
Exit system administration