Siemens Hicom 150 E Office Service Manual page 535

Hide thumbs Also See for Hicom 150 E Office:
Table of Contents

Advertisement

Hicom 150 E Office Rel.1.0 Service Manual - 7.9 Tenant Service
11. Enter routes
17-12 => Call Management Out - Route Assignment
12. 17-13 => Call Management Out - Route Overflow
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step
1.
Options
2.
Classes of service, CON matrix
3.
Classes of service, Group assignment
4.
Classes of service, Station
5.
Classes of service, Day
6.
Classes of service, Night
7.
System Parameters, Diversion / VPL
8.
Incoming Calls, Ring assignment per line
9.
Lines / networking, Trunks
10. Lines / networking, Routes
The configuration of two tenants is described in detail in
guidelines".
Performing Feature Check
Check the feature for error-free functioning as follows:
Step
1.
Customer A has line 1 and 2.
2.
Customer B has line 3 and 4.
3.
Both customers should be able to seize the line with "0".
4.
The lines are assigned to the extensions via traffic restriction groups.
5.
The extensions of customer A are entered in TRG1 and the circuits of customer A in TRG2.
6.
The extensions of customer B are entered in TRG3 and the circuits of customer B in TRG4
7.
The TRG groups for the extensions and circuits of customer A are assigned a TRG from the
other side.
8.
The extensions of customer A are assigned a TRG from the other side for the extensions of
customer B.
9.
The extensions of customer A are assigned the incoming TRG for the circuits of customer B.
10. The TRG groups for the extensions and circuits of customer B are assigned the mutual TRG.
11. The extensions of customer B are assigned the incoming circuits of customer A.
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_79.htm (4 of 5) [06/04/2000 13:11:17]
Action
Chapter 8, "Configuration
Action