Hicom 150 E Office Rel.1.0 Service Manual - 8.2 Call detail recording using a call charge computer (GCM, Teledata)
8.2 Call detail recording using a call charge
computer (GCM, Teledata)
Settings in the system
Programming with Hicom Assistant T
Step
Code
1.
*95 31994 Start system administration
2.
22-13-1
3.
22-13-2-11 Select output port:
4.
22-13-2-12 Select interface:
5.
11-3-1
6.
11-3-3
7.
11-7
Programming with Hicom Assistant E
Step
1.
Port settings for CDRC
System status -> Call charges -> Output format
The baud rate can only be set with Assistant T!
|
Siemens
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_82.htm [06/04/2000 13:12:13]
Action
Set baud rate
(2400 bd or 9600 bd)
U
or V.24
P0/E
1 or 2 for OfficePro
1 to 5 for OfficePoint/OfficeCom
(interface 2-5* must be installed)
Set call data record output to "Compressed" Output:
Set incoming calls to "No"
Set call log to "No"
* = interface 2-5 set permanently to 2400 bd
Activity
|
Home
|
First Page
|
Previous Page
|
Next Page
Display
System Administration
2400 or 9600 bd
Port:
0 = none
1 = V.24 port
2 = U
port
P0/E
V.24 Port
Compressed
Output: No
Output: No
|
Search
|