Hicom 150 E Office Rel.1.0 Service Manual -
4.2 Installation of Hicom 150 E OfficeCom,
OfficePoint, OfficeOne

4.2.1 Overview

Chapter contents
This chapter discusses the following topics:
Installation of the Hicom 150 E OfficeCom, OfficePoint and OfficeOne communication
systems.
It describes the predominantly used installation procedures, information about supplementary
equipment and expansions can be found
Configuration (board configuration).
Danger
The system must only be installed by authorised service personnel.
Tools and equipment required
The following items are required for the installation of the Hicom 150 E OfficeCom, OfficePoint,
OfficeOne systems:
Tools:
- Diagonal cutting pliers, telephone pliers, flat-nosed pliers
- Slotted screw drivers, from 2 to 8 mm
- Pozidriv cross-point screwdrivers, size 1 and 2
- Electric drill, hammer
- Level, metric rule
Equipment:
- Hicom Assistant T or Hicom Assistant E
- Digital multimeter for testing earth connections and partial voltage
- Hicom 150 E Office (electronic) Service Handbook

4.2.2 Procedure for installing Hicom 150 E OfficeCom, OfficePoint

Step
1.
Select the installation site (is generally already predefined)
2.
Unpack the components
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_4fc.htm (1 of 9) [06/04/2000 13:04:51]
Installation activity
Section 6.2
and
Chapter
10.