Recall - Siemens Hicom 150 E Office Service Manual

Hide thumbs Also See for Hicom 150 E Office:
Table of Contents

Advertisement

Hicom 150 E Office Rel.1.0 Service Manual - 10 Special equipment
9.
F8 F7
Exit system administration
The result of this programming is that call forwarding - no answer is performed even when the
PhoneMail port is dialled directly.
A callback after a display message is received is always executed via the initiator's port. This is not
the group but a PhoneMail port.
Memo for Hicom can only be configured by the subscribers (call internal 1 and follow the voice
prompting).
In the case of call forwarding to internal 1, the box is activated when the user leaves the workstation.
Call forwarding when busy / free can be configured for individual extensions or all extensions by
means of Call Management.
Example 2: During day service, the exchange and extensions 13 and 14 are to be forwarded to Memo
after 4 rings; during night service, call forwarding - no answer is to be performed immediately.
Step
Entry
1.
*95 31994 Start system administration
2.
16 18 1
Call destination lists (list 12)
3.
16 18 5
Number of call cycles (list 12)
4.
16 18 3
Extern call, Day (Call No. display 11)
Extern call, Day (Call No. display 13)
Extern call, Day (Call No. display 14)
5.
16 18 1
Call destination lists (list 11)
6.
16 18 5
Number of call cycles (list 11)
7.
16 18 4
Extern call, Night (Call No. display 11)
Extern call, Night (Call No. display 13)
Extern call, Night (Call No. display 14)
8.
F8 F7
Exit system administration
Remarks
Call forwarding - no answer must always be performed to Memo.
For example, if call destination list 11 (option 16) refers immediately to the voice mail group, the box
answers as in the case of a direct extension call (display box).
Memo programming is described in the manual provided with "Memo for Hicom".
Password list for Memo for Hicom:
Customer password (VOICEMAIL / EXCHANGE) 1 2 3 4
Technician password (wrench)
DTMF tracer (initiated via technician menu)
Recalling a voice mail port causes the intercept position to be called.
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_10.htm (3 of 17) [06/04/2000 13:08:49]
Action
5 9 9 1
# 5 9 5
Set time, set date
Display
System Administration
Mbr 1: call
Mbr 2: Grp 1
Call cycles: 4
Call No. 11: 12
Call No. 13: 12
Call No. 14: 12
Mbr 1: call
Mbr 2: Grp 1
Call cycles: 1
Call No. 11: 11
Call No. 13: 11
Call No. 14: 11
Set time, set date

Advertisement

Table of Contents
loading

Table of Contents