Hicom 150 E Office Rel.1.0 Service Manual - 8.40 Mozart CD/Genius announcement device at the SLA board
Operation as announcement
Announcement type: announcement
Relay 1: type: announcement - time: 5 x 100 ms - extension: a/b call number
Relay 2: type: after timeout - time: n x 100 ms - extension: a/b call number
(n x 100 ms = length of the announcement)
Programming via Hicom Assistant T
Step
Entry
1.
*95 31994 Start system administration
2.
26-1
Select type
3.
"Announcement" type
* 20
4.
+
Next actuator
5.
"After timeout" type
* 12
6.
F7
Return to: Actuators
7.
2
Select react time
8.
React time actuator 1 (5 = 5ms)
* 5
9.
+
Next actuator
10.
React time actuator 2 (200 = 20s)
* 200
11.
F7
Return to: Actuators
12.
3
Enter the call number of announcement port under
"Assigned ext"
13.
Announcement port call number for actuator 1
* 124
14.
+
Next actuator
15.
Announcement port call number for actuator 2
* 124
16.
F7 / F8
17.
14-11
Enter the station type as the default
18.
Enter the extension
# 124
19.
F8-F7
End system administration
|
Siemens
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_840.htm (2 of 2) [06/04/2000 13:14:46]
Action
|
Home
|
First Page
|
Previous Page
System Administration
Actr No. 1: -
Actr No. 1: Announcement
Actr No. 2: -
Actr No. 2: After timeout
Actr No. 1: 255
Actr No. 1: 5
Actr No. 2: 255
Actr No. 2: 200
Actr No. 1: -
Actr No. 1: 124
Actr No. 2: -
Actr No. 2: 124
Ext 11: default
Ext 124: default